Mobile
VHDL Online Help Prev Page Prev Page
Table of Contents
Access Type
Aggregate
Alias
Allocator
Architecture
Array
Assertion Statement
Attributes (predefined)
Attributes (user-defined)
Bit
Bit_Vector
Block Statement
Boolean
Case Statement
Character Type
Component Declaration
Component Instantiation
Composite Type
Concatenation
Configuration Declaration
Configuration Specification
Constant
Delay
Driver
Entity
Enumeration Type
Event
Exit Statement
Expression
File Declaration
File Type
Floating Point Type
Function
Generate Statement
Generic
Group
Guard
Identifier
If Statement
Integer Type
Library Clause
Literal
Loop Statement
Name
Next Statement
Null Statement
Operator Overloading
Operators
Package
Package Body
Physical Type
Port
Procedure
Process Statement
Range
Record Type
Report Statement
Reserved Word
Resolution Function
Resume
Return Statement
Scalar Type
Sensitivity List
Signal Assignment
Signal Declaration
Slice
Standard Package
Std_Logic
Std_Logic_1164 Package
Std_Logic_Vector
String
Subtype
Suspend
Testbench
Type
Type Conversion
Use Clause
Variable Assignment
Variable Declaration
Vector
VITAL
Wait Statement
Waveform

Physical Type

Formal Definition

Physical type is a numeric scalar that represents some quantity. Each value of a physical type has a position number that is an integer value. Any value of a physical type is a straight multiple of the primary unit of measurement for that type.

Simplified Syntax

type type_name is range left_bound to right_bound

units

  primary_unit_name

  secondary_unit_name = number primary_unit_name

  secondary_unit_name = number primary_unit_name

  . . .

end units type_name

type type_name is range left_bound downto right_bound

units

  primary_unit_name

  secondary_unit_name = number primary_unit_name

  secondary_unit_name = number primary_unit_name

  . . .

end units type_name

Description

A physical type allows to define measurement units for some physical quantity, like length, time, pressure, capacity, etc.

The range, specified at the beginning of a physical type, defines the minimum and maximum values of a given quantity expressed in the base units (see primary unit declaration below). The bounds of the range of a physical type should be in the form of locally static expression. The expression is classified as locally static if it is possible to determine its value without running the code. The value of an expression used as a range for a physical type must be of integer type. It is legal to use negative bounds.

At the core of a physical type declaration is the definition of a primary unit, and optionally, multiple secondary units. The primary unit serves as the base unit for representing values of the specified type. The secondary units are defined as multiplicity of primary units or previously specified secondary units. Their declarations may contain only integer literals.

Each value of a physical type has a corresponding position number, which is the number of primary units represented by that unit name. This way values specified in different units of the same type can be compared (Example 2).

For all physical types, both TIME and user-defined, relational and arithmetic operators can be used.

The VHDL standard predefines only one physical type: TIME, which is defined in the STANDARD package.

The value of one unit can be written in short form using the name of the unit only (i.e. without the value 1 - Example 3).

Examples

Example 1

type CAPACITY is range 0 to 1E5
units
  pF; -- picofarad
  nF = 1000 pF; -- nanofarad
  uF = 1000 nF; -- microfarad
  mF = 1000 uF; -- milifarad
  F = 1000 mF; -- farad
end units CAPACITY;

 
The primary unit in this example is one picofarad and the maximum value of the CAPACITY type object is 105 pF.

Example 2.

type DISTANCE is range 0 to 1E5
  units
    um; -- micrometer
    mm = 1000 um; -- millimeter
    in_a = 25400 um; -- inch
  end units DISTANCE;
variable Dis1, Dis2 : DISTANCE;
Dis1 := 28 mm;
Dis2 := 2 in_a - 1 mm;
if Dis1 < Dis2 then ...

 
Both, a comparison and an arithmetic operation can be performed on visually different measurement units as long as they are defined as the same type with the same base unit.

Example 3

SomeVar := mF;

 
This assignment means that the variable SomeVar will be assigned the value of 1 mF.

Important Notes

  • Physical types are not synthesizeable. As a result, delays in signal assignments are not synthesizeable as well.

  • It is not allowed to use floating point values in physical type declarations, i.e. if a conversion from millimeters to inches (25.4 mm = 1 in) would have to be performed, then millimeters could not be used as the base unit.

 